Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
Electrical specification
Mains supply voltage: 230V ~ 50 / 60 Hz
Operating voltage: 27Vdc
Wiring: From 0,5 mm2 (500m max) to 2,5 mm ²
Batteries: 2 x 12V/7,2AH
Maximum current supplied: 1A
Mechanical characteristics
Dimensions (mm) / weight (without batteries): 300x370x118 (h x w x d) / 2Kg
IP rating: IP 31
Climatic characteristics
Operating temperature: 0°C to 50°C
Inputs/outputs
AR4D base detection module: 4 detection lines (128 points)
1 monitored programmable input: external power supply state monitoring (standard configuration), external sounders
line activation, external reset panel
1 monitored sounders line: 24V/450mA
1 monitored external power supply output: 24V/450mA
4 programmable open collector outputs: alarm, pre-alarm, disabled, test, system fault, power supply
fault, fault warning, evacuate, active, buzzer on,
reset: 40V/0,1A
1 Alarm NC/NO & 1 Fault NC/NO relay contact: 30V/1A
Options
REP4R, R4P2, R7P2, & R12P2 4, 7, & 12 potential free contact relays boards 30V/1A
EX4A4 detection module 4 detection lines (32 det./line)
DEAG extinguishing module
- Extinguishing actuators line (solenoid or pyroelectric), 24Vdc/1,2A
- Indicators/sounders line, 24Vdc/1A
- Manual extinguishing line
- Inhibition line
- Pressure contact line
- External power supply
Description
ALPHA 4/8/12, modular, compact and economic, is the adapted solution for small installations.
It is microprocessor controlled with SMD technology and with panel programming it is easy to use and install.
With its 4 zones in the basic version and its design, it is adapted for small installations.
Thanks to its optional modules, ALPHA 4/8/12 can be extended to 12 detection zones maximum (384 conventional points) or 2 extinguishing channels maximum (1 extinguishing channel per extinguishing module). Thanks to its 2 slots ALPHA 4/8/12 can provide the following optimal solutions:
4 detection zones + 2 extinguishing channels
8 detection zones + 1 extinguishing channel
12 detection zones
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “ALPHA 4/8/12 Conventional fire detection panel” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE
-
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
-
0 out of 5
Global Fire Addressable Panel JUNO NET
- Fully expandable system from 1-96 Loops with distributed intelligence for added security
- Up to 256 devices per loop (TBA)
- Up to 96 Loop sounders with 32 individually programmable addresses per Loop
- Compatible with major analogue addressable communications protocols
- 2 Fire output changeover relays and 1 Fault output relay (NC)
- Open collector outputs for Fire, Fault and pre-alarm remote indication
- 2 fully monitored sounder outputs on main panel and each sub panel
- Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
- Redundant network communication via RS485, TCP/IP & Fiber Optics
- 384 programmable zones
- 512 fully programmable sounder and I/O groups
- Event Log 2000 entries FIFO
- Backlit LCD display 4 row * 40 characters
- Multiple programming options, onboard keypad, Remote IR(optional), PS2 Keyboard and GFE Connector software
- Windows™ based PC Graphics package ODYSSEY for alarm management and reporting(Optional)
- Multiple Language support (menu selectable)
- MODBUS (ASCII & RTU) and BMS support
-
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software