HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
Electrical specification
Mains supply voltage: 230Vac (-15%, +10%), 50Hz (±10%)
Operating voltage 24Vdc
Wiring: 2 x 1mm² min, shielded / Length = 2000m max
Batteries: 2 sealed lead-acid batteries connected in series 12V / 7Ah
Autonomy without mains 24 hours in standby mode and 30 minutes in alarm Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 1.2A
Mechanical characteristics
Dimensions (mm) / weight (without batteries): H x W x D = 300 x 370 x 120 / 3 Kg
Material/colour: ABS 5V/RAL 7016
IP rating: 31
Climatic characteristics
Operating temperature/storage temperature: -10°C to 50°C/+10°C to 50°C
Operating relative humidity/storage relative humidity: 93% R.H./ 80% R.H.
Inputs/outputs
Number of points/zones: 128/99
Fire detection lines: 2 loops or 4 open lines
Fire alarm management: Alarm, pre alarm, alarm confirmation, hours management day / night mode
Memory events: Up to 1000 events with date and hours
Fire alarm output: 1 alarm NC/NO free contact relay
General fault output: 1 fault NC/NO free contact relay (active in standby state)
Programmable outputs: Optionally 7 (R7P2) or 12 (R12P2) programmable free potential or resistive relays
boards (alarm, pre alarm, fault, panel signalizations/events)
Programmable inputs: 2 x inputs for external event management commanded by NO or NC contact
(activation/deactivation sounders line, reset, fault, power supply fault, technical input)
Serial communication ports: 2 RS232 communication ports for external printer/remote control panel and for
programming of the panel from the PC
Monitored sounders line: 1 x 24V/1A (shared with 24Vdc output)
External power supply: output 1 x 24V/400mA (shared with sounders line)
Description
HEPHAIS 128 is an interactive fire detection panel. Complying with EN54-2 and EN54-4 standards, HEPHAIS 128 is reliable and easy to use equipment. Associated to interactive 05 detectors range, HEPHAIS 128 constitutes the ideal fire alarm compact system. Providing as well 4 open lines or 2 loop lines, it is adapted to all types of required topologies and can manage up to 128 devices (detectors, manual call points, modules). Adapted to a large scale of application, HEPHAIS 128 can answer to requirements of buildings like hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office buildings, back office centres, etc, thanks to its various and numerous outputs allowing many signalling and command orders.
Field configuration, self learning or manual setting constitute very useful start up modes which make HEPHAIS 128 installation a quick and sure operation. The software TELEHEPHAIS128 (upload/download data) permits to configure advanced functionalities and manages all the capacities of the panel up to 99 zones and 99 groups of command.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 128 2 Loops Addressable Panel” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
Conventional Sounder VALKYRIE CS
VALKYRIE CS
Conventional Wall Mount Sounder/ Beacon
The VALKYRIE CS is a wall mounted Conventional Sounder/ Beacon with low power consumption. Four different
tones are available and selected using DIL switches 1 and 2.
Both continuous and pulsing outputs are provided via separate negative supply connections allowing for the
presence of differentiated evacuation and alert sounds. -
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control -
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
Reviews