Conventional Smoke Detector GFE-C
Key Features
- Dual LEDs for 360º visibility
- Advanced detection and communication protocols
- Easy installation and maintenance
- Sleek low-profile housing
- Durable sensor head, no need for replacement
- SMD circuit board design. High quality and reliability guaranteed
- Sensor Base Option: Regular GFE Detector Base or Deep Base
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Key Features
- Dual LEDs for 360º visibility
- Advanced detection and communication protocols
- Easy installation and maintenance
- Sleek low-profile housing
- Durable sensor head, no need for replacement
- SMD circuit board design. High quality and reliability guaranteed
- Sensor Base Option: Regular GFE Detector Base or Deep Base
TECHNICAL SPECIFICATIONS | |
MODEL | GFE-S-2L |
2/4 WIRE | 2 |
SUPPLY VOLTAGE | 10.8 V to 33 V DC |
STANDBY CURRENT | 80 μA |
ALARM CURRENT (12/24V) | 22/55 mA |
SURGE CURRENT (MAX.) | 160 μA |
ALARM TEMPERATURE | - |
PERMISSIBLE CURRENT (MAX.) | 80 mA |
FREQUENCY | 1-3 Seconds |
CERTIFICATION | EN54-7 |
Description
GFE-C
2 wire conventional detectors with remote LED output
The GFE-C series of conventional detectors have been designed to be fully compatible with the Global Fire
Equipment’s range of conventional control panels.
Certified to EN54-5 and EN54-7, these detectors are available in Optical, Heat and combined Smoke/Heat detector
versions.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Conventional Smoke Detector GFE-C” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
6 ZONE WALK THROUGH GATE UOUOU MODEL: CP200
- Cp-200 is basically having 6 Zones
- Each six zone is divided from head to toe to detect high to low level
- 0-99 sensitivity levels are all working to 0.2mm substance too
- 24 led pair lights for indication of metal in suspected
- low-high two types of alarms
- Working power: 30 W, Working power: (100 v-240 v)+-10%
Standard: GB15210-2003
-
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
Reviews
There are no reviews yet.