HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
Electrical specification
Mains supply voltage: 230Vac (-15%,+10%), 50Hz or 60Hz
Operating voltage: 26.4V to 29 Vdc
Wiring: 2 x (0,6 to 1,5) mm² max, shielded / Length = 1500m max
Batteries: 2 x 12V/7Ah
Autonomy without mains: 1 hours in alarm (command)
Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 5 A
Mechanical characteristics
Dimensions (mm) / weight (without batteries) 320 x 610 x 175 (h x w d) / 5Kg (without batteries)
Material/colour ABS 5V/RAL 7035
Climatic characteristics
Operating temperature / Storage temperature -10°C to 50°C
Operating relative humidity / Storage relative humidity 93% R.H./ 80% R.H.
Inputs/outputs
Base: Max number of points / Max number of zones 400 points/1000 zones
Base: Fire detection lines 2 loops or 4 open lines
Fire alarm management Alarm, pre alarm, alarm confirmation, hours management
day/night mode
Memory events Up to 2700 events with date and hours
Programmable outputs (fire alarm, fault, test zone, disabled
point...) 3 x free contact relay outputs 50V/0,3A
Programmable inputs (power. supply fault, reset, sounders
activation...)
2 x monitored inputs for external event management (fault,
reset...)
2 x monitored inputs on front panel
Serial communication ports
RS232 communication port programming with PC
RS422 communication port for Jbus protocol for graphic
monitoring
On front panel
RS232 for external printer
2 x RS485 communication port for remote front panel
(redundant communication)
Sounders line 2 x monitored outputs 30V/1A (for the 2 lines)
External power supply output 1 x 24V/0,5A
Internal options
C20R, 20 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R7P2, 7 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R12P2, 12 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
External options
ALPHA RE remote control and indicating panel Serial connection (from 1 to 20 panels)
Description
HEPHAIS 1600 NE is a control and indicating equipment (CIE) with zone and point address localization
using microprocessor-based technology. It is designed to meet the requirements of standards EN54-2
and EN54-4.
HEPHAIS 1600 NE is an interactive-addressable panel and it can manage up to 400 devices on 2
loops of detection or 128 addresses on 4 lines.
The panel is made of a basis CPU board and control front panel. Optional remote front panel, relay
module boards and sounder line splitter are also available.
With its new functionalities, HEPHAIS 1600 NE provides a flexible solution for all Fire Detection
Systems (FDS.
HEPHAIS 1600 NE is reliable and easy to use equipment. Associated to interactive 05 detectors range,
It is adapted to all types of required topologies and can manage up to 400 detectors or manual call
points, that can be equipped of short-circuit isolator.
Adapted to a large scale of application, HEPHAIS 1600 NE can answer to requirements of buildings like
hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office
buildings, back office centres, thanks to its various and numerous outputs allowing many signalling and
command orders.
Field configuration, scheduled sensitivity and the manual setting constitute very useful start up modes
which make HEPHAIS 1600 NE installation a quick and sure operation.
The software TELEHEPHAIS1600 (download data) allows to configure advanced functionalities and
exploit all the capacities of the panel up to 1000 zones and 256 command groups
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 1600 Addressable Panel” Cancel reply
Related Products
-
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
D-link 05 port Gigabit switch Model: DGS-1005A
High-Speed Networking
Gigabit ports allow you to connect up to five devices
for fast file transfers and smooth media streaming
Save Energy Automatically
EEE compliance reduces energy consumption
without sacrificing performance while cutting down
on your power bill
Eco-Friendly and Economical
Economical yet innovative design runs cool and quiet,
making for an unobtrusive addition to the workplace Connectivity
Five Gigabit Ethernet LAN ports for high-speed
wired connections
Cable Diagnostics Function notifies users of
cable conditions through product LEDs
Green Ethernet Features
Reduces power to a port when no link is
detected
Adjust power to a port by detecting the length
of the connected Ethernet cable -
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation.
Reviews
There are no reviews yet.